Metrologic Instruments IS8000 Barcode Reader User Manual


 
27
A
PPENDIX
B
Default Settings
Many functions of the scanner can be configured, or enabled/disabled. The
factory programs the scanner to a set of default parameters. These defaults are
marked with an asterisk (*) in the default column on the following pages.
Unmarked parameters show the unavailability for that protocol. To speak with
the host system properly, the scanner must be configured to match the systems
individual requirements. Not all functions support all communication protocols. If
the protocol supports a function, a check mark appears on the chart.
P
ARAMETER
D
EFAULT
RS-232 RS-422
L
IGHT
P
EN
INTERFACE FORMAT
RS-232 (RS-422) *
Light Pen
No Comm
Test Mode
Only
CODE TYPES
All UPC/EAN *
Code 39 *
Full ASCII Code 39
MOD 43 Check on Code 39
Code 93 *
Code 128 *
Codabar *
Interleaved 2 of 5 (ITF) *
MOD 10 Check on ITF
Do Not Scan EAN-8
Do Not Scan EAN-13
Do Not Scan UPC-E
Do Not Scan UPC-A
Paraf
UCC Supplemental Codes Special firmware required
2 Digits Supps
5 Digit Supps
977 (2 Digit Supps)
Bookland
Redundancy 2 Digits
Redundancy 5 digits
Require Supps
100 msec to find Supps *