Microsoft UNO-3074 Webcam User Manual


 
UNO-3074 User Manual 28
2.7.10
Cascaded 32-bit Counter
You can also cascade
counter
0
and
counter 1 together
as one 32-bit
counter/timer, and it’s
configured
by control bit
- CTR32Set.
2.8 Power Input
UNO-3074
comes with a Phoenix connector
that
carries 16~36
VDC exter-
nal power input,
and features
reversed
wiring protection. Therefore, it will
not cause any damage to the system
by reversed wiring
of ground line and
power line.
(Please refer to Figure 2.11 for location of power input)
The UNO-3074 supports two
individual power
inputs
(P1/P2).
(
Please
refer to Appendix
A.7 for wiring of P1 and P2)
Figure 2.11: Location of Power P1 and P2
Table 2.17: 32-bit Counter Control Bit
0 Disable (Default)
1 Cascade counter 0 and counter 1 into one 32-bit counter
Note: UNO-3074 provides built-in examples to show how
to deliver counter functionality. Refer to console
mode examples in C:\Program Files\Advan-
tech\UNO\UNO_IsaDIO\Examples\Console. (Please
install DI/O driver from the UNO CD to use these
examples)