Control Panel Messages
5
CF2001P 5-25
6
Move the levers (one on each end
of the oil-coating unit) in the direc-
tion of the arrows and carefully pull
out the paper.
7
While holding the levers on the ends
of the oil-coating unit, move the unit
back to its original position.
8
Fully move the two lock release le-
vers for the oil-coating unit in the di-
rection of the arrows.
9
Close the upper right-side door.
10
Close the right-side door.
CAUTION
The area around the fusing unit is extremely hot.
➜ Touching anything other than the indicated levers around the fusing
unit may result in burns.
➜ If you get burnt, immediately cool the skin under cold water, and then
seek professional medical advice.