Mitsubishi Electronics LVP-S120A Projector User Manual


 
16
AUTO POSITION button
When the source is selected to RGB and the image is
not in the right place, set to display as blight signal
as possible, then press the AUTO POSITION button
on the remote control. If the image is still not in the
right place.
Set screen to the brightest display as possible
(e.g., full-screen display of the Trash window)
before deploying the automatic adjustment
function.
If the screen saver is running, turn off the screen
saver before using the automatic adjustment
button.
5. Adjust the focus with the focus ring by turning it.
6. Adjust the image size with the zoom ring by turn-
ing it.
The volume from the speaker
Press the volume + or button to change the volume
from the speaker.
The volume buttons do not work when MENU se-
lection bar or MENU is displayed.
The volume buttons do not work when the source is
selected to PC CARD.
Turning off the projector
7. Press the POWER button.
The message POWER OFF? YES : PRESS AGAIN
appears on the screen.
To exit from this mode, press any button except
POWER, LASER, mouse pointer, R/L-click,
STILL and VOLUME + and - button.
8. Press the POWER button again.
The light source lamp will be turned off.
Pressing the POWER button again will shut off the
light source lamp, but the exhaust fan continues to
operate for 120 seconds to cool down the light source
lamp and LCD panels. In this time, the lamp indi-
cator will be turned off from flashing.
9. Turn off the main power switch. When turning off
the main switch, the POWER indicator turns off.
In cases where the main power switch is acciden-
tally turned off when either the intake/exhaust
fan or the power source lamp is in operation, allow
the unit to cool down for 10 minutes with the
power turned off. Repeat step 3 when turning on
the power source lamp. If the lamp does not turn
on immediately, repeat this step two or three
times. Replace the lamp if it should still fail to
turn on.
Caution:
When you have finished using this equipment, wait
120 seconds for the exhaust fans to stop. Then turn
off the main switch and unplug the power cable from
the wall outlet, for safety purposes.
After the lamp is turned off, the lamp cannot be
switched on again for 60 seconds as a precaution-
ary measure. It will take another 60 seconds before
the lamp indicator goes off. If you wish to turn on
the projector again, wait until the indicator is off
then press the POWER button.
The exhaust fan runs rotate faster automatically
when the temperature around the projector becomes
high.
When the temperature around the projector becomes
much higher, the sign of TEMP!! blinks red on the
screen. If the temperature stays in high, the lamp will
be shut off automatically .
The projector automatically shuts off when the
lamp is used up in about 2,000 hours and not used
until lamp replacement.
wide
zoom ring
tele
far
near
focus ring
30
To operate projector power ON (continue)