EN-26
2. INSTALLATION menu
ITEM SETTING FUNCTION
LAMP MODE STANDARD Select this option when you want to view images in a well-lit room.
LOW Select to moderate the intensity of the lamp. The fan operating sound is
reduced and the lamp lifetime becomes longer.
AUTO POWER ON
ON / OFF When ON is chosen, the lamp is automatically lit when the power cord is
plugged in the wall outlet. Choose ON when using the projector mounted on
the ceiling.
The projector is in the stand-by mode when the lamp is off. Use the remote
control to turn on the lamp.
AUTO POWER OFF
OFF / 5 - 60min Use to set the time elapsed before the projector enters the stand-by mode
when there is no signal input from the source.
SPLASH SCREEN
ON / OFF Choose ON to display the splash screen when the power is turned on.
BACK COLOR BLUE / BLACK Use to change the color of the screen that appears when no signal is supplied.
IMAGE REVERSE
OFF Select when viewing images from the front with the projector installed on the
oor.
MIRROR Select when viewing images projected from the behind of the screen with the
projector installed on the fl oor.
INVERT Select when viewing images projected from the behind of the screen with the
projector installed on the ceiling.
MIRROR INVERT Select when viewing images from the front with the projector installed on the
ceiling.
TRIGGER OUT ON / OFF Choose ON to output the trigger output signal (12 V) from the TRIGGER
terminal when the lamp illuminates.
TEST PATTERN
CROSS HATCH
Select to show the test cross hatch pattern.
LENS LOCK
ZOOM/FOCUS LOCK
Use to enable or cancel the FOCUS LOCK and ZOOM LOCK.
LENS SHIFT LOCK
Use to enable or cancel the LENS SHIFT LOCK.
LENS SHIFT RESET
Use to reset the position of the lens to the factory setting.
When LAMP MODE has been set to LOW, the lamp mode changes from STANDARD to LOW about one minute
after turn-on.
When the lamp mode is switched, the projected image may fl icker. This is not a product malfunction.
Do not change the setting of LAMP MODE frequently.
To cancel the test pattern, press any button.
IMAGE
REVERSE
OFF
OFF
BACK COLOR
OFF
opt.
STANDARDLAMP MODE
A V MEMO R Y 1
LENS LOCK
OK
AUTO POWER
ON
AUTO POWER
OFF
INSTALLATION
TRIGGER OUT
OFF
ON
ON
BLUE
SPLASH
SCREEN
TEST PATTERN
CROSS HATCH
2. INSTALLATION menu