Multitech 3100 Network Router User Manual


 
22
MultiFRAD 3000-Series User Guide
If your data device is an Asynchronous device, then click on Asynchronous check box, and
set the Baud Rate by clicking on the Baud Rate down arrow and the drop down list box
displays the baud rate. Also, select the Word Length, Parity, Stop Bits, etc. for your device.
Refer to the user documentation for the parameters of the data device.
23. Click on OK when you are satisfied with your data port configurations.
24. If you enabled PPP in the WAN Ports Default Setup dialog box, proceed to step 36.
If you enabled Frame Relay in the WAN Ports Default Setup dialog box, the Frame Relay
DLCI Default Setup dialog box is displayed with all the groups inactive.
Your MultiFRAD can detect DLCIs and the frame relay management type when the unit is
connected to an active frame relay network service. At this point your MultiFRAD is not
communicating with the frame relay network. But if you know your DLCIs and want to add
them at this point, you can continue with the next step. If you wish to wait until your
MultiFRAD is communicating with the frame relay network, proceed to step 36 to finish
installing your software.
25. Click on the New (+/-) button and the Frame Relay New DLCI dialog box is displayed with
Enter DLCI Number field active. Enter a DLCI number that was provided by your service
provider at subscription time.