Multi-Tech Systems MVP30-60 Scanner User Manual


 
MultiVOIP User Guide Technical Configuration (Analog)
166
Analog Telephony Interface Parameters
(for MVP210/410/810)
The following parameters must be known about the PBX or telco
central office equipment to which the analog MultiVOIP will connect: :
Analog Phone Parameters
Ask phone company or
telecom manager.
Needed for:
MVP810
MVP410
MVP210
Analog Telephony Interface Parameters:
Record for this VOIP Site
@
Which interface type (or “signaling”) is used?
E&M_____ FXS/FXO_____
If FXS, determine whether the line will be used for a
phone, fax, or KTS (key telephone system)
If FXO, determine if line will be an analog PBX
extension or an analog line from a telco central office
If E&M, determine these aspects of the E&M trunk
line from the PBX:
What is its Type (1, 2, 3, 4, or 5)?
Is it 2-wire or 4-wire?
Is it Dial-Tone or Wink?
Write down the values for these telephony parameters. You will need
to enter these values in the “Interface” screen in the Configuration
section of the MultiVOIP software.