National Instruments NI-488.2 Switch User Manual


 
Chapter 4 Debugging Your Application
NI-488.2 User Manual for Windows 4-2 www.natinst.com
NI Spy records and displays all NI-488.2 calls, as shown in Figure 4-1.
Figure 4-1. NI-488.2 Calls Recorded by NI Spy
For more information about using NI Spy, select Help»Help Topics in
NI Spy or refer to Chapter 5, NI Spy Utility.
Global Status Variables
At the end of each NI-488.2 call, the global status variables (
ibsta
,
iberr
,
ibcnt
, and
ibcntl
) are updated. If you are developing an
NI-488.2 application, you should check for errors after each NI-488.2 call.
If a NI-488.2 call failed, the high bit of
ibsta
(the
ERR
bit) is set. For a
failed NI-488.2 call,
iberr
contains a value that defines the error. In some
error cases, the value in
ibcntl
contains even more error information.
You can use NI Spy to determine which NI-488.2 call is failing. Once you
know which NI-488.2 call fails, refer to Appendix B, Status Word
Conditions, and Appendix C, Error Codes and Solutions, for help
understanding why the NI-488.2 call failed. This information is also
available in the NI-488.2 online help. For instructions on accessing the
online help, refer to the Using the NI-488.2 Documentation section in
About This Manual.