Problem Solving 5-17
STATUS LED
Error Message
Color State
Suspected module Description Procedure
Cor0 -12vAlm 09
Amber Lit PCI module #1
Fatal -12-V power voltage alarm
(upper limit)
Cor0 Bus PERR 01
Green Blink PCI module #1 PCI bus parity error
Cor0 Bus SERR 01
Green Blink PCI module #1 Fatal PCI bus error
Cor0 CLK Alm 00
Amber Blink CLOCK board Clock alarm (lower limit)
Cor0 CLK Alm 02
Amber Lit CLOCK board Fatal Clock alarm (lower limit)
Cor0 CLK Alm 07
Amber Blink CLOCK board Clock alarm (upper limit)
Cor0 CLK Alm 09
Amber Lit CLOCK board Fatal Clock alarm (upper limit)
Contact your sales agent.
Cor0 FAN Alm 01
Amber Blink PCI module #1 Cooling fan1 alarm
Cor0 FAN Alm 02
Amber Blink PCI module #1 Cooling fan2 alarm
Cor0 FAN Alm 03
Amber Blink PCI module #1 Cooling fan3 alarm
Cor0 FAN Alm 04
Amber Blink PCI module #1 Cooling fan4 alarm
Cor0 FAN Alm 05
Amber Blink PCI module #1 Cooling fan5 alarm
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
Cor0 offline
Green Blink PCI module #1 PCI module logically isolated Start the PCI module by ft sever
utility or dismount and remount
that module. If not solved by the
above, contact your sales agent.
Cor0 removed
Green Blink PCI module #1 PCI module detached Dismount and remount the PCI
module. If not solved by the
above, contact your sales agent.
Cor0 Temp Alm 00
Amber Blink PCI module #1 Temperature alarm (lower limit)
Cor0 Temp Alm 02
Amber Lit PCI module #1
Fatal temperature alarm (lower
limit)
Cor0 Temp Alm 07
Amber Blink PCI module #1 Temperature alarm (upper limit)
Cor0 Temp Alm 09
Amber Lit PCI module #1
Fatal temperature alarm (upper
limit)
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
Cor1 +12vAlm 00
Amber Blink PCI module #2 12-V power voltage alarm (lower
limit)
Cor1 +12vAlm 02
Amber Lit PCI module #2 Fatal 12-V power voltage alarm
(lower limit)
Cor1 +12vAlm 07
Amber Blink PCI module #2 12-V power voltage alarm (upper
limit)
Cor1 +12vAlm 09
Amber Lit PCI module #2 Fatal 12-V power voltage alarm
(upper limit)
Cor1 +2.5vAlm 00
Amber Blink PCI module #2
2.5-V power voltage alarm (lower
limit)
Cor1 +2.5vAlm 02
Amber Lit PCI module #2 Fatal 2.5-V power voltage alarm
(lower limit)
Cor1 +2.5vAlm 07
Amber Blink PCI module #2 2.5-V power voltage alarm (upper
limit)
Cor1 +2.5vAlm 09
Amber Lit PCI module #2 Fatal 2.5-V power voltage alarm
(upper limit)
Cor1 +3.3vAlm 00
Amber Blink PCI module #2 3.3-V power voltage alarm (lower
limit)
Contact your sales agent.