NEC 320Lb-R Server User Manual


 
Configuring Your System 3-13
*Pressing the Power switch for at least 4 seconds shuts down power to the server.
Thermal Sensor Submenu
Feature
Choices or
Display Only Description Your Setting
Thermal Sensor Disabled
Enabled
When enabled determines if
the BIOS will disable boot (if
temperature is not within a
safe range).
Upper Limit
7 – 48 - 80
Specifies the upper
temperature limit for bootup
restriction in Celsius. Specify
a value greater then the Lower
Limit by at least 8 using the +
and – keys.
Lower Limit
0 – 5 - 73
Specifies the lower limit
temperature for boot-up
restriction in Celsius. Do not
specify 4 degrees or lower.
Specify a value smaller than
the "Upper Limit" value by at
least 8 using + and keys.
Wake On Events Submenu
Feature
Choices or
Display Only Description Your Setting
Wake On LAN Disabled
Enabled
Enable or disable the remote
power-on feature via the
network.
When "Enable" is selected,
change the "AC-LINK" setting
in the "System Hardware" to
"Stay Off".
Console Redirection Submenu
Feature
Choices or
Display Only Description Your Setting
Serial Port Address
Disabled
On-board COM B
Select a serial port to connect
the HW console.
Selecting "On-board COM B"
changes "Boot-time Diagnostic
Screen" to "Enabled".
Baud Rate 57.6K
19.2K
Enables the specified baud
rate.
Flow Control
No Flow Control
XON/OFF
Enables flow control.
Console
Connection
Direct
Via Modem
Indicate whether the console is
connected directly to the
system or a modem is used to
connect.