NEC EXPRESS5800 Computer Accessories User Manual


 
- 78 -
Event
ID
Message Action
6684
Physical Disk is marked as DEAD
due to PFA condition of the disk
Replace the failed HDD.
6685
Physical Disk is marked as DEAD
due to forced offline state
Replace the failed HDD.
6149
RAID migration has
encountered a physical disk
error
Physical disk error detected. If it cannot be fixed, replace
the HDD.
6150
RAID migration has
encountered a physical disk
error
Migration aborted. Please contact the sales representative
for reconstruction of the array.
6154
Array was made Incomplete
due to missing NV Watermark
An error occurs during Migration. Please contact the sales
representative for reconstruction of the array.
7681
Rebuild is completed
Rebuild is completed. Check the status of the logical drive.
7682
Rebuild is paused
Rebuild is stopped. Restart rebuilding as soon as possible.
7683
Rebuild is resumed
No specific action required.
7684
Rebuild is stopped
Rebuild is stopped. Restart rebuilding as soon as possible.
7687
Rebuild is aborted due to an
internal error
Rebuilding aborted. Please contact the sales representative.
7689
Rebuild is queued
No specific action required.
7696
Auto rebuild can not start
The capacity of unconfigured physical drive is not capable
of rebuild. Replace a drive with proper capacity.
7697
Rebuild stopped internally
Rebuilding aborted. Please contact the sales representative.
1542
Redundancy check is aborted
due to an internal error
Check HDD and cables and replace it if any failure exists.
1543
Redundancy check
encountered inconsistent
block(s)
If any error occurs in HDD, replace that HDD. If no error
occurs in HDDs, back up the system data and replace all
the HDDs.
1546
Redundancy check task is
stopped internally
Check HDD and cables and replace it if any failure exists.
8192 SMART error is received
Replace the failed HDD.
The above table shows the event IDs in decimal. The events listed in the table are reported to
NEC ESMPRO Manager. The symbols such as %1 in messages are padding characters.