NetComm NP2500 Switch User Manual


 
NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide 35
YML842 Rev1
Trap Setting
The Trap Setting enables the device to monitor the Trap through the Web Management Utility. Set the Trap IP
Address of the manager where the trap is to be sent.
Figure 32. Trap Setting
System Events:
Monitoring the system’s trap.
Device Bootup:
a trap when booting up the system.
Illegal Login:
a trap when there is using a wrong password login, and it will record
from where the IP to be login.
Twisted Pair Port Events:
Monitoring the twisted pair port status.
Abnormal* Receive Error:
a trap when there are receive data error in twisted pair port.
Abnormal* Transmit Error:
a trap when there are transmit data error in twisted pair port.
Abnormal*:
50 error packet count within 10 seconds.
PoE Events:
Monitoring the PoE ports status.
PoE Power fail:
A trap when the port’s power source fails or the PD64012 fails.
Power on/Power off:
A trap when the PoE port’s power is on and down.
Power over current:
A trap when the PoE port’s power is over current.
Power short circuit:
A trap when the PoE port’s power circuit was short.
Power threshold on/off:
A trap when the radio of the system power supply larger than or smaller
than the System power Threshold setting.