Nortel Networks 5399 Switch User Manual


 
Nortel Networks 5399 Access Switch Hardware Installation Guide
Chapter 2 Installing the Model 5399 Remote Access Concentrator Module
2-20
6. Press the space bar within 10 seconds.
After a few seconds, the following message is displayed:
Monitor Mode selected, please wait for Confidence tests
to complete.
After about a minute, the following message is displayed,
followed by the monitor prompt:
System Reset - Entering Monitor Mode
monitor::
7. If you want to clear out the stored parameters from a
previously used slot (reset the hub slot), continue on with
Step 8. If you do not want to reset the hub slot (if, for
example, you are performing a hot swap), skip to Step 16.
8. On the service port terminal, press then -T to
display the Slot Selection menu.
9. Press s.
The Supervisory Module Main Menu is displayed.
10. Press m toselecttheModuleInformationmenu.
The following prompt is displayed:
Enter slot # (1-14):
11. Enter the slot number of the module you want to boot.
The module information and status are displayed and you are
prompted to reset the module, set the module configuration to
default, or return to the previous menu.
12. Press d to select the module configuration default.
The following message is displayed:
Are you sure you want to set module DEFAULT
configuration? (Y/N):
Enter Control