Omron CJ-Series Network Card User Manual


 
15
CX-Process Tool and Monitor
Connections to PLC
Note: The CX-Process functions that can be used depend on the version. For details, refer to the operation manuals (Cat. No.: W372-E1-@ and
W373-E1-@).
Note: 1. When using Windows Me, the CPU must be a Pentium 150 MHz or higher.
2. Peripheral Bus cannot be used when FinsGateway V3 is used.
Connections to PLC
The following 4 methods can be used to connect to a PLC.
Note: 1. The Windows 2000 and XP operating systems are supported. (Windows 95, 98, and Me are not supported.)
2. When CX-Server is used for communications, CX-Programmer can be simultaneously connected via the same COM port.
3. The Windows 95 operating system cannot be used.
Item
Specifications
Offline functions ITEM data settings for function blocks
Software connections for analog signals
Displaying and printing text strings (annotation)
pasted on function block diagrams and ladder
diagrams.
Instructions for step ladder blocks and commands for
sequence table blocks
Tag settings for CX-Process Monitor
Engineering unit display setting
Segment Program parameter setting
Construction of user screens
Online functions Transfer of function block data (Downloading/Upload-
ing for Loop Control Boards/Units.)
Starting/stopping all function blocks (LCU/LCB)
Monitoring system operation: Monitoring and
controlling the System Common block (including
LCB/LCU load rates)
Validating LCB/LCU operation: Checking function
block connections (including starting and starting
individual function blocks), validating ladder
diagrams and sequence tables, and monitoring
ITEMs
Tuning PID constants and other parameters
(fine tuning and autotuning)
Initialization of Loop Control Unit memory (RAM)
External backup specifications
User screens
Overview screen
Control screen
Tuning screen
Trend screen
Graphic screen
Operating guide message screen
System screens
Alarm history screen
System monitor screen
Operation log screen
Communications network Communication driver
FinsGateway V3 FinsGateway Version
2003 (See note 1.)
CX-Server V2.2
Host Link Connection via PLC's peripheral port or
RS-232C port
Supported. (Serial Unit version is used.) Supported.
(See note 2.)
Peripheral Bus Not supported. Supported. Supported.
(See note 2.)
Controller Link Connection to PLC with Controller Link Unit
via Controller Link Support Board (PCI
board).
Supported. (See note 3.)
(CLK (PCI) version is used.)
Supported.
Connection to PLC with Controller Link Unit
via Controller Link Support Board (ISA
board).
Supported. (CLK (ISA) version is used.) Supported.
Ethernet Connection to PLC with Ethernet Unit via
Ethernet Board.
Supported. (Ethernet version is used.) Supported.