Omron CJ-Series Network Card User Manual


 
32
Ordering Information
CPU Bus Units
CPU Bus Units
Controller Link Units
Controller Link Units, New Models
Controller Link Units, Old Models
New models are fully compatible with old models and provide enhanced functionality, such as an increase in the number of send words from
1,000 to 4,000 words. Select a new model when ordering.
Note: Use the following special cable for shielded, twisted-pair cable.
ESVC0.5 x 2C-13262 (Bando Electric Wire: Japanese Company)
ESNC0.5 x 2C-99-087B (Nihon Electric Wire & Cable Corporation: Japanese Company)
ESPC 1P x 0.5 mm
2
(Nagaoka Electric Wire Co., Ltd: Japanese Company)
Li2Y-FCY2 x 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
1 x 2 x AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
#9207 (Belden: US Company)
Repeater Units
Note: 1. Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks. 62-node configurations, and con-
verting part of the network to optical cable.
2. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable
with connector.
3. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
Relay Terminal Block
Note: Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in
advance on the Unit in a Wired Controller Link network. Relay Blocks cannot be used on Controller Link Support Boards.
Unit
classifi-
cation
Product
name
Specifications No. of unit
numbers
allocated
Current con-
sumption (A)
Model Standards
Communica-
tions cable
Communi-
cations
type
Duplex
support
Max. Units
mountable
per CPU
Unit
5 V 24 V
CJ1
CPU
Bus
Unit
Control-
ler Link
Unit
Wired shielded
twisted-pair cable
(See note 2.)
Data links
and mes-
sage service
No 8 1 0.35 ---
CJ1W-CLK23
UC1, N, L,
CE
Unit
classifi-
cation
Product
name
Specifications No. of unit
numbers
allocated
Current con-
sumption (A)
Model Standards
Communica-
tions cable
Communi-
cations
type
Duplex
support
Max. Units
mountable
per CPU
Unit
5 V 24 V
CJ1
CPU
Bus
Unit
Controller
Link Unit
Wired shielded
twisted-pair cable
(See note 2.)
Data links
and mes-
sage service
No 8 1 0.35 --- CJ1W-CLK21-V1 UC1, N, L,
CE
Unit classification Specifications Model Standards
Controller Link
Repeater Unit
Wire-to-wire Model CS1W-RPT01 UC1, CE
Wire-to-Optical (H-PCF) Model (See note 2.) CS1W-RPT02
Wire-to-Optical (GI) Model (See note 3.) CS1W-RPT03
Unit classification Specifications Model Standards
Relay Terminal Block
for Wired Controller
Link Unit
Use for Wired Controller Link Units (set of 5). CS1W-TB101 ---
C
S1W-RPT01
PWR
T/R1
T/R
2
SL
1
TE
R S
W
T
ER SW
ON
S
L
2
D
C
2
4
V
IN
P
U
T
1
B
A
U
D
2
R
A
T
E
S
W
1