Opticon LMD 1135 Scanner User Manual


 
Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 19
Appendix B
Computer Programming Commands
All commands must be preceded by an 'ESC' character (ZZ) and be followed by a 'Carriage Return'
character (1C). Shaded areas indicate factory default settings.
Enable Disable Global Defaults
U2 Enable Factory Default Settings
Z1 Transmit software version
Z2 Save all values set by command
Z3 Display software settings (inc,
prefix/suffix).
Only Add Symbology Selection
A0
Enable all symbologies
B0 Disable all symbologies
J0 Enable all UPC and EAN
A2 B2 Code 39
A3 B3 Codabar (NW-7)
A4 B4 IATA
A5 B5 Code 93
A6 B6 Code 128 (Inc. EAN-128)
A7 B7 MSI/Plessey
A9 B9
Telepen
J1 R1 UPC (A/E)
J2 R2 UPC (A/E)+2
J3 R3 UPC (A/E)+5
J4 R4 EAN (13/8)
J5 R5 EAN (13/8) +2
J6 R6 EAN (13/8) +5
J7 R7 2 or 5 Industrial
J8 R8 2 or 5 Interleaved
JD JZ
TriOptic
RA R9
SCode
Enable Disable Options for UPC
E2 UPC-A (13 Digits) Transmit
leading zero & CD
E3 UPC-A (12 Digits) No leading zero
but transmit CD
E4 UPC-A (12 Digits)Transmit
leading zero but No CD
E5 UPC-A (11 Digits) No leading zero
& no CD transmitted
E6 UPC-E (8 Digits)Transmit leading
zero & CD
E7 UPC-E (7 Digits) No leading zero
but transmit CD
E8 UPC-E (7 Digits) Transmit leading
zero but no CD
E9 UPC-E (6 Digits) No leading zero
& no CD transmitted
6Q Transmit UPC-E as is
6P Transmit UPC-E as UPC-A
Enable Disable Options for EAN-8 & EAN-13
6K 6J EAN-13 Transmit CD
6I 6H EAN-8 Transmit CD
IA IB Enable ISBN translation
HO HN Enable ISSN translation