Opticon LMD 1135 Scanner User Manual


 
Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 35
8. Options for Codabar (NW-7) (Continued)
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END Programming Menu
[[
H7
Do not calculate check digit
I8
%
H6
Calculate check digit
I7
HI
Inter-character Gap Check – No
check
IJ
HH
Inter-character Gap Check
II
%
-X
Default algorithm
.Y
%
-Y
Enables alternate decode
algorithms. May improve
performance on certain I 2 of 5,
Code 39, Codabar or MSI/Plessey
bar codes.
.Z
Codabar (NW-7) Format
Start
Character
1 to 42
data digits
Check
digit
Stop
Character
A . . . . . . . . T
a . . . . . . . . t
A . . . . . . . . A
a . . . . . . . . a
Codabar (NW-7) has four different start/stop character schemes as shown above. The check digit is
optional and, if present, would be the last character.
If the scanner is programmed to calculate the check digit and the bar code is not printed with a
check digit, the bar code will not be read.