The Manual Entry Key 1/2/3/4 fields accept hexadecimal inputs as the encryption
he remaining fields in the Security Panel are described below.
a. Deny Unencrypted Data Frames: if checked, the firmware will block
b.
c. oose how many frames the
keys. If 64 bits encryption is enabled, each key field allows the user to enter up to
10 hexadecimal characters. If 128 bits encryption is enabled, each of the key
field allows up to 26 hexadecimal characters.
T
unencrypted data frames from being received.
Transmission key: This allows user to choose from key 1 to key 4 for
transmission. The default key is set to Key 1.
WEP key factor: this list box allows user to ch
Initialize Vector (IV) is reused. It contains four options: every frame, every
10 frames, every 50 frames, and every 100 frames. The default key factor
is Every 100 frames.
When the Apply button is pressed, the program validates all entered data and
prompts the user to re-enter the data if any of the input data is invalid. If all data
is valid, the entered data will be applied to the radio unit. When the Cancel
button is clicked, all entered data under Security Panel is discarded.
14