7
Installation
Instructions
Installation precautions
(continued)
Be absolutely sure to use the supplied brackets and
screws to install the camera.
p Do not mount the unit by employing any methods other
than those specified.
p Do not remodel the mounting bracket or mounting screws
provided with the unit.
Before installation, always disconnect the power plug
When installing, always use the supplied components.
Do not disassemble or modify the wall mount adaptor.
Tightening up the mounting screws
p Tighten up the screws and bolts securely to the degree
that is appropriate for each of the materials used in the
mounting location and structures.
p After tightening up the screws and bolts, check that there
is no unsteadiness and that the parts have been tightened
securely.
p Use the specified tools and tighten the screws firmly.
p Tighten up the screws using the specified torque driver.
Do not use electrical drivers or impact drivers.
When the unit is no longer going to be used, do not
leave it lying around, but be absolutely sure to dispose
of it properly.
For details on how to remove the unit, refer to “Removing the
camera” (page 15).
When installing, transferring or disposing of the unit, be
absolutely sure to hold it by its pedestal area.
Problems may result if the camera head is held or rotated.
Do not attach a filter, hood, extender or other parts to the
unit.
Use the dedicated AC adaptor and power cable provided
with the unit.
Connect the AC adaptor and power cable to the power inlet
securely.
Installing the AC adaptor
p Do not place the adaptor directly onto a ceiling panel or
other such surface.
Extreme danger is posed when water has collected on the
surface as a result of leaking rain, for instance.
Secure the adaptor firmly to the bottom or other surface of
a reinforcing member made of channel steel where dust
and other foreign matter will not accumulate.
(Refer to page 12.)
p Secure the adaptor firmly so that there will be no chance
that it will fall off or fall down.
Secure it using a strength which can withstand the mass
(approx. 340 g [0.75 lb]) of the AC adaptor.
Install the accessory AC adaptor near the main power
outlet, and position it in such a way that its power plug
can be plugged into and unplugged from the outlet easily.
When connecting the AC adaptor to a power outlet on the
ceiling or on any other surface where dust may collect, wipe
off the dust on the power plug at periodic intervals as an anti-
tracking measure.
Power switch
This unit does not have a power switch. The power turns
on when its power plug is connected to a power outlet.
When the power is turned on, the pan, tilt, zoom and
focusing operations are performed. Before proceeding with
maintenance, be absolutely sure to disconnect the power
plug from the power outlet.
Connecting the power cable
Be absolutely sure to connect the power cable of the
AC adaptor through a circuit breaker using one of the
following methods.
(1) Connect the power cable through a power control unit.
(2) Connect the power cable to a circuit breaker in a
power distribution panel with a contact distance of
3.0 mm or more.
Use a circuit breaker which is capable of shutting
off all the poles of the main power supply with the
exception of the protective ground conductor.
(3) Install the AC adaptor near the power outlet, and
connect it through the power plug.
Grounding
Before using the unit, check that the grounding
wire has been fastened securely.
If there is a possibility of noise interference
Either wire the cables so that the power cable (ceiling light
cord) of AC 100 V* [AC 220 V**] or more, and the signal
cable are placed at least 1 meter (3.3 ft) apart. Alternatively
run each cable through its own metal conduit. (The metal
conduits must be grounded.)
* : For AW-HE60HN, AW-HE60SN
** : For AW-HE60HE, AW-HE60SE
Radio signal interference
If the unit is positioned near a TV or radio transmitting
antenna or a strong electrical field or magnetic field (such as
that generated by a motor, transformer or power lines), its
images may be distorted and/or the images may be affected
by noise.
When connecting the cables, ensure that the connector
areas will not be subject to any load.
Doing so may cause malfunctioning.
Allowing the generated heat to escape
This unit allows the heat generated inside to escape from its
surfaces.
Do not install the unit in a location where it will be surrounded
by walls or other surfaces and where heat will be trapped. In
addition, the heat is dissipated to the bottom panel which will
warm up over time: This is normal and not indicative of any
trouble.
IMPORTANT
p The product name and its electrical ratings are