Paradyne 3911 Network Card User Manual


 
8-13910-A2-GN32-40 September 1998
Test Branch
Overview
The Test branch of the Top-Level menu allows you to initiate various modem tests. Use these
tests if you are having data communication problems, such as periodic character loss, random
errors, or constant format errors. By the process of elimination, you can usually isolate the fault
in your system.
There are six selections under Test: Abort, Self (Self-Test), Loc Analog Loop (Local Analog
Loopback), Rem Digital Loop (Remote Digital Loopback), Loc Digital Loop (Local Digital
Loopback), and Pattern. The only tests that can operate concurrently on a single modem are
Pattern with a Local Analog Loopback and Pattern with a Remote Digital Loopback. If any test
is operating, besides the two combinations just mentioned, it must be canceled before starting
another test.
The Test branch only initiates and cancels tests. If any parameters need to be set, refer to Test in
Chapter 5, DCP Configuration.
Test
Status
Status Configure PList Control
SubHS
Call_Setup Tlk/Data Security Remote
Abort Self Loc_Analog_Loop Rem_Digital_Loop Loc_Digital_Loop Pattern
8