Paradyne 8310 MVLt Network Card User Manual


 
Traps
B-2
8000-A2-GB26-10January 1999
Event MIBTrap #CommentSeverity
xDSL margin
normal
normal Margin estimate now above
customer set threshold.
103 hot_xdsl.mib
(Enterprise MIB)
xDSL port
failure
major Processor detected bad DSL
modem chip set.
5 hot_xdsl.mib
(Enterprise MIB)
xDSL port
operational
normal Processor now communicating
with DSL modem.
105 hot_xdsl.mib
(Enterprise MIB)
xDSL port
speed low
warning Port speeds decreased to lower
bound thresholds.
2 hot_xdsl.mib
(Enterprise MIB)
xDSL port
speed normal
normal Port speed now above lower
bound threshold.
102 hot_xdsl.mib
(Enterprise MIB)
xDSL port
speed normal
normal Port speed now above lower
bound threshold.
102 hot_xdsl.mib
(Enterprise MIB)
xDSL SN
selftest fail
warning Self-test failure from an
Service Node.
19 hot_xdsl.mib
(Enterprise MIB)
xDSL test start normal Test started by any means. 6 hot_xdsl.mib
(Enterprise MIB)
xDSL test clear normal Test over. 106 hot_xdsl.mib
(Enterprise MIB)
Dynamic filter
injection failure
warning Cannot inject or delete
dynamic filters to Service Node
on port
n.
10 hot_dhcp.mib
(Enterprise MIB)
Ethernet link
down
major 2 MIB II
(RFC 1213)
Ethernet link up normal 3 MIB II
(RFC 1213)
Warm start warning Power on reset. 1 MIB II
(RFC 1213)
Self-test failure minor Sent if any portion of the
Access Node’s restart/self-test
fails.
16 hot_sys.mib
(Enterprise MIB)
SN device
failure
major Operating software has
detected an internal device
failure but the Service Node is
operating.
18 hot_xdsl.mib
(Enterprise MIB)
SN device
mismatch
minor Service Node identified on
port
n
does not match device
described in port configuration
role.
07 hot_xdsl.mib
(Enterprise MIB)
SN device
mismatch clear
minor Service Node on port
n
now
matches port configuration
table.
107 hot_xdsl.mib
(Enterprise MIB)
SN fatal reset Variable binding field contains
device failure code.
20 hot_xdsl.mib
(Enterprise MIB)