Paradyne 8540 Network Card User Manual


 
F-1
8000-A2-GB20-20
November 1997
5446 RTU Setup
F
5446 RTU Overview
The RADSL 5446 RTU has an IP configuration table that is updated through an
SNMP agent. The configuration table contains IP address and subnet mask
information.
The network service provider for the 5446 RTU provisions the IP address
information into the 5446 RTU’s configuration table. The 8546 DSL card
interoperates with the 5446 RTU. An NMS communicates via SNMP to Get or Set
objects within the SNMP agent’s control to update the IP configuration table. The
5446 RTU supports MIB objects relative to their RFC description.
The following sections explain:
H Accessing 5446 RTU MIBs
H Using Standard MIBs (MIB II)
H SNMP Traps supported by the RTU
For more information about the 5446 RTU installation, see the
HotWire 5446
Remote Termination Unit (RTU) Customer Premises Installation Instructions.
Accessing 5446 RTU MIBs
There are three methods available to update the 5446 RTU IP configuration table:
H Paradyne’s IP Injection Tool
H NMS DCE Manager
H MIB Browser
The IP Injection Enterprise MIB must be used to finalize the 5446 RTU setup. The
IP Injection Tool and the Enterprise MIBs are available on Paradyne’s World Wide
Web site:
http://www.paradyne.com