5446 RTU Setup
F-4
8000-A2-GB20-20November 1997
" Procedure
From an SNMP workstation:
1. To load the MIB, access the Paradyne World Wide Web site:
http://www.paradyne.com
2. Select:
Service & Support
!
MIBs
!
HotWire DSL
!
pdndce.mib
3. Enter the IP address of the RTU.
4. Press Options to change Set Community to Private.
5. Locate the MIB group pdn-ipinjection.
From a MIB browser, do a single set with a unique entry containing the required
fields. Refer to Table F-1 for IP injection group objects.
Using the null entry:
" Procedure
1. Change the Null entry by entering the IP address (ipInjectionAddress).
2. Change the mask by entering a subnet mask (ipInjectionMask).
3. Change the Type to Service Provider or Host (ipInjectionType).
4. Select Set.
5. Do a Get or Query to verify before continuing to the next entry.
Using the table index:
" Procedure
1. Enter the three fields into the Index:
ipInjectionType
ipInjectionAddress
ipInjectionMask
2. Enter the status value:
ipInjectionStatus
3. Select Set.
If a null entry does not appear, the table is full. Delete entries from the table by
setting the ipInjectionStatus to invalid.