Patton electronic 1092 Network Card User Manual


 
2. If the above test indicates no errors are present, move the
V.52 toggle switch DOWN, activating the “511/E” test with
errors present. If the test is working properly, the local
modem's red “ER” LED will glow. A successful “511/E” test
will confirm that the link is in place, and that the Model 1092’s
built-in “511” generator and detector are working properly.
NOTE: The above V.52 BER tests can be used independently
of the Remote Digital Loopback tests. This requires two
operators: one to initiate and monitor the tests at the local
Model 1092, and one to do the same at the remote Model
1092. In this case, the test pattern sent by each Model 1092
will not be looped back, but will be transmitted down the line to
the other Model 1092. While one operator initiates test, the
other monitors for errors.
29
APPENDIX A
PATTON MODEL 1092 SPECIFICATIONS
Transmission Format: Synchronous or asynchronous
Transmission Line: Single unconditioned twisted pair
Clocking: Internal, external or receive loopback
Distance: Distance, max, all data rates:
10.1 miles (16.4km) on 19 AWG (0.9mm) wire
7.2 miles (11.5 km) on 22 AWG (0.64mm) wire
5.0 (8 km) on 24 AWG (0.5mm) wire
3.4 (5.5 km) on 26 AWG (0.4mm) wire
Interface Modules: EIA RS-232/CCITT V.24, RS-232/530,
CCITT V.35 and CCITT X.21
Data Rates: Synchronous 32, 56, 64 & 128 kbps; Asynchronous
0 - 38.4 kbps
Diagnostics: V.52 compliant bit error rate pattern (511/511E
pattern) generator and detector with error injection mode; Local
Line Loopback and Remote Digital Loopback, activated by front
panel switch or via serial interface
LED Status Indicators: TD, RD, CTS, CD, DTR, NS(no signal),
ER (error) and TM (test mode)
Connectors: RJ-45 on line side; DB-25 female, M/34 female or
DB-15 female on serial interface side, depending upon which
interface module is installed.
Power: 120/230 VAC (switch selectable), 50-60 Hz; 100-253 VAC,
50-60 Hz (universal input option); 48 VDC (option). 5 watts.
Temperature Range: 32-122°F (0° -50°C)
Altitude: 0-15,000 feet
Humidity: 5 to 95% noncondensing
Dimensions: 7.3” x 6.6” x 1.62” (185mm x 168mm x 41mm)
Weight: 2.01 lbs. (1.0kg)
30