APPENDIX A
SPECIFICATIONS
A.1 LAN CONNECTION
Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
CopperLINK Connection:
RJ-45 or Terminal Block
A.2 TRANSMISSION LINE
Two-wire unconditioned twisted pair.
A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE
Line Rate: 50 Mbps, symmetric upstream/downstream. Additional
symmetric and asymmetric rates are available via DIP switch settings.
Distance: 6,000 ft (1.8 km) at 1 Mbps upstream/4 Mbps downstream
Note
Distances depend on selected line rate and line conditions. See
Appendix D on page 20 for details.
A.4 COPPERLINK SURGE SUPPRESSOR
SIDACTOR with maximum current surge: 20 kA (8/20
μ
s).
A.5 LED STATUS INDICATORS
Power (Green)
CopperLINK: Link (Green)
Ethernet: Link (Green) & Activity (Flashing Green)
A.6 POWER SUPPLY
External AC and DC options:
AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
DC: 12 VDC, 24 VDC and 48 VDC
Power consumption: 450 mA at 5 VDC
A.7 TEMPERATURE RANGE
-10 to 70°C
A.8 HUMIDITY
Standard
:Up to 90% non-condensing
Conformal Coated:
85% condensing humidity from -10 to 35°C
A.9 DIMENSIONS
1.5H x 4.13W x 3.75D in.(3.81H x 10.5W x 9.53D cm)