If you attempt to modify any conÞguration parameters via the EOC (by
changing (EOC variables), the RocketLink-G will not execute your
changes.
3.3 CONFIGURING THE DIP SWITCHES
(V.35, X.21, and Ethernet
Models)
The Model 3088RC is equipped with three sets of DIP switches, which
you can use to conÞgure the RocketLink-G for a broad range of applica-
tions. This section describes switch locations and discusses the conÞgu-
ration options available.
Note
By default, the RocketLink-G’s DIP switches are all set to “ON”
so the NTU can be conÞgured via the console. If that is how you
will be conÞguring the NTU, skip ahead to the section on conÞg-
uring the console.. Otherwise, read the following sections to
manually conÞgure the DIP switch settings.
Figure 1.
Location of DIP switches on Model 3088RC
The three sets of DIP switches on the Model 3088RC are referred to as
S1, S2 and S3. DIP switch orientation with respect to ON and OFF posi-
tions is consistent for all switches.
The DIP switches S1 and S2 can be conÞgured as either ON or OFF.
S1
S2
Position Function Position Function
S1-1
Data Rate S2-1 Front Panel Switches
S1-2 S2-2 Line Probe
S1-3 S2-3 Annex
S1-4 S2-4 Clock Mode
S1-5 S2-5
S1-6 S2-6 DTE Loops
S1-7 S2-7 DTE Interface Type
S1-8 TX Clock S2-8 Reserved
S1
S2
S3