9 • Diagnostics and Software Upgrades Model 3201 G.SHDSL Integrated Access Device User Guide
106 Ping
Ping
The ping command is executed from the Command Line Interface (CLI). Ping in the 3201/3241 is executed
from the “ip” command. Here is the ping format followed by a valid response.
ip ping 192.168.100.11
ping: PING 192.168.100.11: 32 data bytes
ping: 40 bytes from 192.168.100.11: seq=0, ttl=128, rtt<10ms
Software Upgrades
Software upgrades are required in two scenarios. First, for new features. Second, for standard software upgrades
(at an additional cost).
For standard software upgrades, which are at no charge, contact upgrades.patton.com for the location of the
new firmware and follow these instructions.
1. Get the firmware image from Patton and save on your PC. It is a .tar file and MUST NOT be unzipped!
2. Login to the 3201’s web page on the browser.
3. Click on > System, then > Upgrade
4. Locate the firmware image on this web page.
5. Click on Upgrade.
6. Wait until the upgrading is complete, and then restart the 3201.
7. It is now ready to use with the new firmware.
If you encounter problems with the firmware upgrade, do the following to upload software image into the Pat-
ton 3201/3241 via TFTP. .
Note The Patton 3201/3241 products have a TFTP server built-in, a
TFTP client will be require on the user side to connect to the TFTP
server
Configuration
The Patton products are configured as a TFTP server with the default IP address 192.168.200.10.
Procedure
1. Go to Upgrade.patton.com and download the software upload package. The package contains the follow-
ing files:
Tftplock.key
Tftpupdt.beg
Image
Npimage