Pelco C2624M Switch User Manual


 
C2624M (6/07) 25
Optic Fault LED ( )
Green The optical signal is
being received and
laser is operating
properly.
No action required.
Red The optical signal is
not being received.
Remote module is not
powered on.
Check power connections.
Replace power supply if
necessary.
Fiber optic cable is not
connected.
Check fiber optic
connections.
Fiber optic cable connectors
are dirty or are damaged.
Clean, polish, or replace fiber
optic cable connectors as
necessary.
Fiber optic cable is
defective.
Replace cable.
Optical dB losses in the
fiber optic installation
exceed the optical power
budget specification stated
in the Specifications
section.
Check for problems with the
fiber optic installation, for
example, excessive dB
losses in connectors, splices,
patch panels, cables,
and so on.
Optical dB losses in the
fiber optic installation meet
the optical power budget
specification stated in the
Specifications section;
however, a module is
defective.
Contact Product Support.
Flashing red Laser has shut down. Module is operating in
extreme environmental
conditions; for example,
operating temperature is
below or above recom-
mended range as stated in
the Specifications section.
Ensure that module operates
according to operating
conditions stated in the
Specifications section, and
then cycle the power.
If problem persists, contact
Product Support.
Laser has reached end of
life.
Cycle the power. If problem
persists, contact Product
Support.
Table C. Troubleshooting with Front-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action