Pelco C2624M Switch User Manual


 
28 C2624M (6/07)
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)
Amber Port is set to
10BASE-T full-
duplex mode.
If 10BASE-T full-duplex opera-
tion is desired, no action is
required. If 10BASE-T full-
duplex operation is not
desired, refer to the Setting
10BASE-T/100BASE-TX Port
Modes of Operation section in
this manual for information.
Flashing amber Port is set to
10BASE-T half-
duplex mode and
network collision
has occurred.*
Normal or excessive colli-
sions occur on a half-duplex
link.*
If a normal collision occurs, no
action is required.
If a problem with the network
exists due to excessive
collisions, do any of the
following as appropriate:
If half-duplex mode is not
required, set the TX Mode
switch to full-duplex mode
by means of autonegotia-
tion or by forcing the mode
(refer to the Setting
10BASE-T/100BASE-TX
Port Modes of Operation
section in this manual for
information).
If half-duplex mode is
required, do any of the
following as applicable:
Replace network cable
if it is defective or if it
is not the proper cable
type. Use Category 5e
or higher cable.
Ensure that cable is
proper length. Cable
length must not exceed
328 feet (100 meters).
Replace the network
interface card (NIC) if it
is defective or if it is
incompatible.
Segment the network.
(Continued on next page)
Table D. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action