25
within the specified range. The Message Center will adjust the specified rate to the
nearest available supported rate.
4.2.5 Enable /INT Signal Monitor
Monitor/INT (on INT supported adapters only. Default=OFF)
Enable /INT signal monitoring.
4.2.6 Stop On Busy
StopOnBusy (Default=OFF)
Stop sending I
2
C messages if the adapter returns a "Busy" response to the host
computer.
4.2.7 Stop On Arbitration Loss
StopOnArbLoss (Default=OFF)
Stop sending I
2
C messages if the adapter returns a "Bus Arbitration Loss" response
to the host computer. Bus Arbitration Loss occurs when another I
2
C Bus master
wins arbitration while the adapter is attempting to become a bus master.
4.2.8 Stop On Slave Negative Acknowledgment
StopOnNak (Default=OFF)
Stop sending I
2
C messages if the adapter returns a "Slave Not Acknowledging"
response to the host computer. Slave Not Acknowledging occurs when the adapter
is attempting to become a bus master and no slave device acknowledges the
transmitted slave address.
4.2.9 Beep On Busy
BeepOnBusy (Default=OFF)
Generate a host computer beep if the adapter returns a "Busy" response to the host
computer.