Philips P89LPC907 Computer Monitor User Manual


 
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC906/907/908
ADDITIONAL FEATURES
2003 Dec 8 88
MOV DPTR, #data16 Load the Data Pointer with a 16-bit constant.
MOVCA, @A+DPTR Move code byte relative to DPTR to the accumulator.
MOVXA, @DPTR Move data byte the accumulator to data memory relative to DPTR.
MOVX@DPTR, A Move data byte from data memory relative to DPTR to the accumulator.
Also, any instruction that reads or manipulates the DPH and DPL registers (the upper and lower bytes of the current DPTR) will
be affected by the setting of DPS. The MOVX instructions have limited application for the P89LPC906/907/908 since the part
does not have an external data bus. However, they may be used to access Flash configuration information (see Flash
Configuration section).
Bit 2 of AUXR1 is permanently wired as a logic 0. This is so that the DPS bit may be toggled (thereby switching Data Pointers)
simply by incrementing the AUXR1 register, without the possibility of inadvertently altering other bits in the register.