PLUS Vision UP-800 Projector User Manual


 
E – 27
This section describes the simple maintenance procedures you
should follow to replace the lamp, clean and replace the batteries in
the remote control.
Replacing The Lamp
After your lamp has been operating for 1000 hours or longer, the
“status” light in the cabinet will go on. Even though the lamp may
still be working, replace it at 1000 hours to maintain optimal pro-
jector performance.
CAUTION
DO NOT TOUCH THE LAMP immediately after it has been
used. It will be extremely hot. Allow at least one hour for the
lamp to cool before handling.
DO NOT REMOVE ANY SCREWS except the lamp cover
set screw and two lamp case screws. You could receive an
electric shock.
• Turn off the main power to the projector and disconnect the
power cord. Allow at least one hour for the lamp to cool.
The projector will turn off and be in standing by after 1100
hours of service. If this happens, be sure to replace the lamp.
Lamp replacement procedure
Preparations Carefully turning the projector main unit upside down
in such a way that it does not get scratched makes it easier to replace
the lamp. After the lamp has been replaced, return the projector
main unit to the normal position.
1. Switch off the main power and unplug the power cord.
2. Turn the main unit so that the bottom is up.
3. Remove the lamp housing fastening screws.
4. Slide the lamp cover in the direction of the arrow and remove it.
CAUTION: Do not use a lamp other than the PLUS replacement
lamp.
Order this from your PLUS dealer using your projector's
model number.
5. Remove the three screws for the lamp housing.
Request This projector has a switch for safety.
6. Holding the handle, pull the lamp housing forward and take it off.
7. Install the new lamp housing and fasten with the threescrews.
8. Fasten the three screws for the lamp housing.
9. Install the lamp cover back in its original position and fasten with
the fastening screw.
10.
Reset the lamp time.
Select the lamp usage time menu, then press the ON button on the
remote controller and hold it down for at least ten seconds.
NOTE: If resetting the lamp clock back to zero after 1100 hours of service,
press the "Power Off" (not "Power On") button on the remote control for ten
seconds .
NOTE: When the lamp usage time reaches 1100 hours, it becomes impos-
sible to switch on the power and menus are not displayed. In such a case,
press the remote control OFF button for at least 10 seconds in the standby
state. It is possible to confirm whether there has been reset or not by
checking whether the STATUS indicator is extinguished. Obtain a replace-
ment lamp at the store of purchase for this unit. When ordering a
replacement lamp, specify the UP-800 special replacement lamp - model
name UP-800L (Product code 28-861).