Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP Optimization
Copyright © 2004 Polycom, Inc 103
4.6.1.16 Event Logging <logging/>
The event logging system supports the following classes of events:
ind.gi.x.y.class positive integer Assigns the class (defined above) for this indicator.
ind.gi.x.y.physX IP 300: 0-19
IP 500: 0-159
IP 600: 0-319
IP 4000: 0-247
For GraphicIcon type indicators, this is the x-axis loca-
tion of the upper left corner of the indictor measured in
pixels from left to right.
ind.gi.x.y.physY IP 300: 0-3
IP 500: 0-79
IP 600: 0-159
IP 4000: 0-67
For GraphicIcon type indicators, this is the y-axis loca-
tion of the upper left corner of the indicator measured in
pixels from top to bottom.
ind.gi.x.y.physW IP 300: n/a
IP 500: 1-160
IP 600: 1-320
IP 4000: 1-248
For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.
ind.gi.x.y.physH IP 300: n/a
IP 500: 1-80
IP 600: 1-160
IP 4000: 1-68
For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.
Warning!
Logging parameter changes can impair system operation. Do not change any logging parameters
without prior consultation with Polycom.
Level Interpretation
0 Debug only
1 High detail event class
2 Moderate detail event class
3 Low detail event class
Attribute
Permitted
Values
Interpretation