Powerware 3115 Power Supply User Manual


 
Operation and Configuration
10
Powerware
®
3115 User’s Guide www.powerware.com
Standby Mode
When the UPS is turned off and plugged into a wall outlet or other
power source, the UPS is in Standby mode. The battery recharges when
necessary and the Power On indicator is off, indicating that power is not
available from the rear receptacles.
How to Set DIP Switches
The DIP switches on the rear panel of each unit (see Figure 7) are used
to configure the output voltage and utility power range.
1. The UPS must be completely shutdown.
Turn the UPS off by pressing the
buttononthefrontpanel
and then unplug the UPS.
2. Set the DIP switches according to the DIP switch configurations
in Table 1.
3. Plug the UPS into a wall outlet or other power source and press
the
button to turn the UPS on.
UPS Rear Panel
DIPSwitchDetail
DIP Switches
ON
OFF
4321
Figure 7. DIP Switch Location