Renesas M37641T2-RPD-E Network Card User Manual


 
( 60 / 68 )
(3)When the Program Window is Not Displayed (Target System Not Connected)
Table 6.2 Checkpoints of errors when starting up the emulator debugger (target system not connected)
Error
Not connected to the target system.
Cannot be connect to target system.
Communication error occurred.
Data was not sent to the target.
Communication error occurred.
Data was not received from target.
Target system is not properly built.
M3T-PD38 version is not same as firmware
version in target.
Target MCU cannot be reset.
Reset target system.
Checkpoint
Communication between the emulator system and host
machine is not normal.
Check the connection between the emulator and host
machine.
Check the interface switch on the rear of the emulation
pod.
Check the interface setting of the Init dialog box.
The emulator system is not operating properly.
(1) Download the proper firmware.
See "4.2 Downloading Firmware" (page 40).
(2) Recheck the connection between the PC4701 and
this product.
See "3.6 Connecting the PC4701 and Emulation
Pod" (page 34).
Firmware is not compliant with this emulation pod.
Download the proper firmware.
See "4.2 Downloading Firmware" (page 40).
MCU reset was not correctly controlled when the emulator
system was started up.
(1) The Clock tab setting in the Init dialog box may be set
to 'External'. When the target system is not connected,
set it to 'Internal'.
(2) 'M37640.MCU' may not be set in the MCU tab of the
Init dialog box. Check the setting.