3.2 Connecting the Pod Probe and Emulation Pod
The 7900 Series emulation pod consists of the following 2 products. How to connect them is shown
in Figure 3.7.
(1) Emulation pod: M37900T2-RPD-E
(2) Pod probe: M379xxTx-PRB (designed for each MCU group)
Figure 3.7 Connecting pod probe
(1) Unscrew the 4 screws of the M379xxTx-PRB.
(2) Connect the connectors J3, J4 of the M379xxTx-PRB
and connectors J1, J2 of the M379xxTx-PRBM to the
connectors J3, J4 of the M37900T2-RPD-E's FLX100
and connectors J5, J6 of the M379xxTx-PRB,
respectively.
(3) Fix the M379xxTx-PRB with 4 screws.