Ricoh DSm735 Printer User Manual


 
Maintaining Your Machine
155
7
Changing the Photoconductor
Unit (PCU)
Only use the photoconductor unit
made specifically for this machine.
Follow the procedure below to
change the unit.
Important
Be sure to unplug the power code
from the outlet before changing
the photoconductor unit.
A Open the front door, duplex unit,
and then transfer unit right cover.
B Push the development unit to the
left, and then pull out the photocon-
ductor unit.
C Remove the harness clamps on the
charge unit and cleaning unit of the
new photoconductor unit.
D Push the development unit to the
left, and then install the new photo-
conductor unit.
Note
If the copy quality is still not satis-
factory after replacing the photo-
conductor unit, contact your
service representative.
AdonisC4-AE_zen_F_FM_forPaper.book Page 155 Thursday, May 12, 2005 3:32 PM