RuggedCom RS910L Switch User Manual


 
18
2007 RuggedCom Inc. All rights reserved Rev100
4 Ethernet Ports
4.1 RJ11 Ethernet over VDSL Port
4.1.1 Overview
The Ethernet over VDSL (EoVDSL) port on RS910L operates in pairs with one configured as the
Master and the other as the Slave. In VDSL literature the terms Central Office (CO) or Line
Termination (LT) are used interchangeably for the Master and the terms Customer Premise
Equipment (CPE) or Network Termination (NT) are used interchangeably for the Slave.
Configuration of Master or Slave mode is done through the RuggedSwitch Operating System.
The unit contains one EoVDSL data port that allows connection to Category 3 (CAT-3) unshielded
twisted-pair (UTP) cable with RJ11 male connectors. The figure below shows the RJ45 port pin-out
and LEDs.
Figure 13 - RJ11 port pin-out and LEDs
Pin Signal
3 Ring
4 Tip
Table 2 - RJ11 port pin-out
Status LED Colour Activity Comments
On Master Mode
Mode Green
Off Slave Mode
Solid Link Established
Link / Act Green
Blinking Tx Activity
Table 3 - RJ11 port LED description