Installation
2.3 Power Supply Wiring and Grounding
The RSG2000 family supports dual redundant power supplies, “Power Supply 1”
(PS1) and “Power Supply 2” (PS2). The connections for PS1, PS2 and the fail-
safe relay are located on the terminal block as shown in Figure 16 and Figure 17.
RSG2000 products can be equipped with either a Philips Screw Terminal Block
or a Phoenix Plug Terminal Block. The Philips Screw Terminal Block has Philips
screws with compression plates, allowing either bare wire connections or
crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure
secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before
connecting any wires. The safety cover must be reattached after wiring to
ensure personnel safety. Refer to Table 5 below for a description of each
terminal as well as to sections 2.3.1 through 2.3.3 for power supply wiring
examples.
Figure 16: RSG2000 Series Philips Screw Terminal Block
Figure 17: RSG2000 Series Phoenix Plug Terminal Block
17
© 2008 RuggedCom Inc. All rights reserved Rev100