RuggedCom RSG2300 Switch User Manual


 
Technical Specifications
FX04 SM ST 9/125 1310 -15 -8 -32 -3 20 17
FX05 SM SC 9/125 1300 -15 -8 -31 -7 20 16
FX06 SM LC 9/125 1310 -15 -8 -34 -7 20 19
FX07 SM SC 9/125 1310 -5 0 -34 -3 50 29
FX08 SM LC 9/125 1310 -5 0 -35 -3 50 30
FX09 SM SC 9/125 1310 0 5 -37 0 90 37
FX10 SM LC 9/125 1310 0 5 -37 0 90 37
3.5.3 Gigabit Ethernet (1000Mbps) Optical Specifications
Fixed Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
FG02 SM SC 9/125 1310 -10 -3 -20 -3 10 10
FG03 SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG04 SM SC 9/125 1310 -5 0 -20 -3 25 15
FG05 SM LC 9/125 1310 -7 -3 -24 -3 25 17
SFP Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
50/125 0.5
F51
3
MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
FG52 SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
FG53 SM LC 9/125 1310 -7 -3 -23 -3 40 16
FG54
4
SM LC 9/125 1550 0 5 -23 -3 70 23
GBIC Gigabit transceivers
Order
Code
Mode
Connector
Type
Cable Type
(um)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
FG71 SM SC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG72 SM SC 9/125 1310 -7 -3 -24 -3 25 17
FG73
5
SM SC 9/125 1550 0 5 -23 -3 70 23
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber
quality, and number of patches and splices. Please consult RuggedCom
sales associates when determining maximum segment distances.
2. All optical power numbers are listed as dBm averages.
3. F51 transceivers are rated for -10 to +85°C
4. FG54 transceivers are rated for 0 to +70°C
5. FG73 transceivers are rated for -25 to +85°C
30
Rev100 © 2008 RuggedCom Inc. All rights reserved