Runco CL-810 / SDC-1 Projector User Manual


 
Installation
30 Runco CL-810 Series Owner’s Operating Manual
PRE
L
IMINAR
Y
RS-232 Controller
Connection
Connect a PC or home theater control/automation system (if present) to the RS-232 port
on the CL-810; see
Figure 3-14. Use a standard, 4-wire RJ-11 telephone cable, wired
straight-through.
For more information about using this connection, refer to Serial Communications on
page 69.
Figure 3-14. RS-232 Control System Connection
S-VID /
S-VID
12345
7
896
D-Sub 9-pin female
RJ-11 Male
RJ-11 to
D-Sub 9-pin Adapter
(not included)
1
2
3
4
Yellow
Yellow
Red
Red
Black
Green
Green
Black
RS-232 Adapter Wiring
D-Sub 9-pin female 4-pin RJ-11 Function
22Transmit Data
3 3 Receive Data
5 1, 4 Ground
1, 4, 6, 7, 8, 9 -- Not Connected