Samsung SRP-250 Series Printer User Manual


 
13
Serial Interface Specification
DIP Switch 1 Functions
SW
FUNCTION ON OFF DEFAULT
1 Data Receive Error Ignore
Print
¡°
?
¡±
OFF
2 Hand Shaking XON/OFF DTR/DSR OFF
3 Word length 7 bits 8 bits OFF
4 Parity check Yes No OFF
5 Parity selection EVEN ODD OFF
6 OFF
7
Baud Rate selection Refer to the following table
OFF
8 Hexadecimal dump ON OFF OFF
l NOTE : When the word length is 7 bits, you can not parity check OFF status.
Baud rate selection
Transmission speed SW – 6 SW – 7
1200 baud ON ON
2400 baud OFF ON
4800 baud ON OFF
9600 baud OFF OFF
DIP Switch 2 Functions
MODE SW – 1 SW – 2
Epson OFF OFF
Citizen ON OFF
Star OFF ON