15.4 Specifications
Item Standard or Performance Notes
MODEL E11A202U001 E11A202U001J (*6)
Output capacity 2.0kVA/1.4kW
Cooling system Forced air cooling
Type of Input pulg NEMA 5-20P NEMA L5-30P
(*6) When the plug is NEMA_5-20, the
input and output voltage of UPS are
120V. only (For UL rules.)
Phases Single phase, 2-wire
120V 100,110,115,120V
Voltage
-20% to +15% Double Conversion mode
±
5% Economy /Active Filter mode
±
10% Fixed Economy mode
User settable
(Rated voltage same as output voltage)
Frequency 50Hz or 60Hz
±
10%: Double Conversion mode
±
1, 3, 5%: Economy /Active Filter mode
Power requirements 1.8kVA Max. capacity during battery charging
AC input
Input power factor 0.95 or more During rated output (*2)
Type of receptacle
NEMA 5-20R
×
4 NEMA L5-30R
×
1
Phases Single phase, 2-wire
Voltage 120V 100, 110, 115, 120V (*6) User settable
Voltage regulation
Rated voltage
±
2%
Rated frequency 50Hz or 60Hz
Same as input frequency
(auto selection)
Frequency regulation
Rated frequency
±
0.5% Double Conversion mode
Rated frequency
±
1, 3, 5% Economy/Active Filter
mode
1, 3, 5% selectable
Internal oscillator accuracy
±
0.5%
Voltage waveform Sine wave
Distortion factor of voltage
waveform
Linear load: 3% or less
100% rectifier load: 7% or less
During rated output
Rapid load
change
0%
⇔
100% at transient or output
switch
Power outage,
recovery
Rated voltage
±
5 %
During rated output
Transient
voltage
variation
Rapid input
voltage change
±
10% variation
Response time 5 cycles or less
Load power factor (lag) 0.7 (lag) Variation range 0.7 (lag) to 1.0
Overcurrent protection Auto switch to bypass circuit at 105% or more With auto return function
Inverter 105% 200ms
AC Output
Overload
capability
Bypass 20A or more
Type Small sealed lead battery
Rated capacity
10 A
・
h
20 hour ratio
Number 4 (12V per battery) 4 in direct series
Batteries
Backup time
5 minutes
At 25°C (77°F) ambient temperature,
rated load
Generated heat 250W During Double Conversion mode
Input leakage current 3mA or less
Operating environment
Ambient temperature: 0 to 40°C (32 to 104°F)
Relative humidity: 20 to 90%
(*3)
Acoustic noise 45 dB or less
1 m (approx. 40 inches) from UPS front
panel, 'A' characteristics (linear load)
Safety standard UL1778-4th/C22.2 No.107.3-05-2nd:2005
EMI standard FCC Part 15,Sub partB,Class-A And EN55022 Class-A
Other quotation standards
EN62040-1-1:2003 (For LVD)
EN50091-2:1995 (For EMC)
EN55024:1998/A1:2001/A2:2003 (For EMC)
EN55022:1994/A1:1995/A2:1997 (For EMC)
(*1): The inverter is capable of operation synchronized with AC input and instantaneous switchover
provided that the AC input frequency is within
±
3% (or 1%, 3%, 5%, selectable) of the rated
frequency, and the AC input voltage is within +15% to-20% of the rated voltage.
The UPS enters battery operation with the AC input frequency is outside the specified range.
(*2): When input voltage waveform distortion is under 1%.
(*3): The UPS contains batteries. Battery service life will be foreshortened if the UPS is used in an
environment where the ambient temperature exceeds 30°C (86°F).
(*4): If grounded, the ground phase of the input and output must match according to UPS specifications.