Unit 4: Operation
SATO GT4xxe Series Operator Manual PN 9001138A Page 4-31
Allows determination of which method of configuration has
priority; the relative dip switch or the LCD menu. This screen is
displayed only when the applicable interface card is installed.
Allows selection of the baud rate. Will only appear when the
RS232C interface is installed and the LCD option is chosen
from the prior menu.
Allows setting of the Parity Bit for the RS232C interface. Will not
display if the dip switch priority option is chosen. The interface
card must be installed.
Allows Stop Bit selection for the RS232C interface. Will not
display if the dip switch priority option is chosen.
Allows selection of the data length for the RS232C interface.
Will not display if the dip switch priority option is chosen.
Allows setting of communication protocol. Will only appear if
RS232C or RS422/485 interface is installed (except if the
relative dip switch is set with either as the priority).
Allows setting for output timing of ACK signal for Centronics
interface. Select ON for output outside the busy signal and OFF
for inside the busy signal. Will only display if the Centronics
interface is installed.
INTERFACE MODES (4-4 THROUGH 4-8)
MENU DESCRIPTION
RS-232C/422/485
CONFIGURATION
DIPSW LCD
BAUDRATE
2400 4800
9600 19200
PARITY BIT
NONE ODD EVEN
STOP BIT
1BIT 2BIT
CHARACTER BIT
7BIT 8BIT
PROTOCOL
READY/BUSY
XON/OFF
STATUS2
STATUS3
STATUS4
STATUS5
MULTIDROP
CENTRONICS
ACK SIGNAL
ON OFF