Seagate ST15150N/ND/DC Computer Drive User Manual


 
Barracuda 4 Installation Guide, Rev. E 45
Figure 20. Additional jumper options
Enable parity check of SCSI bus data
(default).
J4
PAR
MTR
DMS
Parity Check option (PAR)
Disable parity check.
Enable motor start. The drive waits for 
the Start Unit command from the host 
before starting the spindle motor.
Motor Start option (MTR)
Disable motor start (default). The drive 
starts according to the Delay Motor 
Start option setting as described below.
Motor start delay equal to the SCSI ID
multiplied by 10 seconds plus 3 seconds. 
For example, if the SCSI ID = 2, the drive 
starts in 23 seconds ((2x10)+3 = 23).
Delay Motor Start option (DMS)
(valid only if the Motor Start 
jumper is not connected)
Disable the delay motor start option
(default).
Pin 1
J4
J01
W/WD drives