SIIG 04-0860A Computer Drive User Manual


 
11
6. Press F10 to exit the BIOS. When asked Do
you want to exit from Marvell BIOS Setup?
press Y to exit and reboot.
Rebuilding a Failed Mirror Set
When a failure to one member occurs, you will be
notified by the RAID BIOS during boot up. The
steps below will guide you in rebuilding a failed
mirror set.
1. Replace the failed drive with one of equal or
greater capacity, then boot the computer.
2. As the BIOS boots press Ctrl+M when
prompted to enter the RAID BIOS.
3. Select New_VD, press Enter. Select Rebuild
then press Enter.
4. Select the new hard drive under Free
Physical Disks.
5. Press Spacebar to select hard drive, then
press Enter.
6. When asked Do you want to rebuild with
selected physical disk on this vd?, press Y
to select Yes. The mirror will begin
rebuilding. Do not interfere with the process
until completion.