Silex technology SX-500-1402 Server User Manual


 
Command Description
Format:
SET SERVEr NAme <name>
SET SNMP CONtact Sets system contact string
The default value is null.
Format:
SET SNMP CONtact <string>
SET SNMP LOCation Sets system location string
The default value is null.
Format:
SET SNMP LOCation <string>
SH SERIAL Displays serial number of the unit
Sample output:
Serial number is 9047595
SH SERVEr Shows server parameters
Sample output:
Serial Server Serial # 9047595
Address: 00-40-17-8A-0E-2B Name: TWC_8A0E2B
Number: 0
Identification: Network Server
Enabled Characteristics:
Link DOWN
SH SERVEr CO Shows server network statistics
Sample output:
Seconds Since Zeroed: 163
Bytes Received:72950
Bytes Sent:18726
Frames Received:752
Frames Sent: 181
Multicast Bytes Rcv'd:64474
Multicast Bytes Sent: 2406
Multicast Frames Rcv'd:626
Multicast Frames Sent:11
Frames Sent, Deferred:2014
Frames Sent,1 Collision: 26
Frames Sent, 2+Collision: 5
Send Failures: 0
Send Failure Reasons: 0
Receive Failures: 503
Receive Failure Reasons: 1
Unrecognized Destination: 0
Data Overrun: 0
User Buffer Unavailable:0
System Buffer Unavailable:1
Console Commands Silex Page 48
Part Number 140-00188-210A