3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0
WRITE EXTENDED (10) (2Ah)
The WRITE (10) EXTENDED (2Ah) command requests that the drive write the data transferred by
the initiator to the medium. Bytes 1 and 9 are ignored.
W
RITE AND VERIFY (10) (2Eh)
The WRPROTECT field and DPO and BYTCHK bits in CDB Byte 1 are all ignored.
V
ERIFY (10) (2Fh)
The VRPROTECT field in Byte 1 is ignored. If the DPO and BYTCHK bits in CDB Byte 1 are not both
zero, or the GROUP NUMBER field in Byte 6 is non-zero, the command is rejected. If any bit in Byte
1 is set other than LUN, or if any bits in Bytes 6 and 9, an Invalid field in the CDB is reported.
Table 25. Write Extended (10) (2Ah) CDB
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (2Ah)
1 Logical Unit Number (RSVD) DPO FUA Reserve Reserve RelAdr
2 (MSB)
Logical Block Address
3
4
5 (LSB)
6 Reserved
7 (MSB)
Transfer Length
8 (LSB)
9 Control