Sony SDX-800V Computer Drive User Manual


 
6.Command Specification LOG SENSE
6-18 SONY AIT-3Ex drive SDX-800V series Ver.1.1
The following parameter codes are supported for each Error Counters Page:
Table 6-17: Error Counter parameter codes
Parameter
Code
Description Parameter
Length (Bytes)
Default
Cumulative
Default
Threshold
0003h Total Errors Corrected (Soft Errors) 4 0 FFFFFFFFh
0004h Total Times Correction 4 0 FFFFFFFFh
0005h Total Groups Processed (Algorithm
Processed)
4 0 FFFFFFFFh
0006h Total Errors Uncorrected (Hard Errors) 4 0 FFFFFFFFh
6.6.5. Last N Error Events List
This page is used to report information on soft and hard errors encountered by the device during normal operation.
Each parameter corresponds to an encountered error and is a report of what type of error occurred and when it
occurred. The format of the page is given below:
Table 6-18: Last N Error Events Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Reserved Page Code (07h)
1 Reserved
2 (MSB) Page Length (n*14)
3 (LSB)
4 (MSB) Parameter Code
5 (LSB)
6 DU (0) DS (1) TSD (0) ETC (0) TMC (00) LBIN (0) LP (0)
7 Parameter Length (0Ah)
8 Parameter Value
17
The Parameter Codes supported are 1 through 30 where 30 is the maximum number of entries in the log page.
If there are no entries, the command will return the Page Header with the Page Length field set to ZERO.
Each error event record contains diagnostic information for a single error encountered by the device. The parameter
codes associated with the error-event records indicate the order in which the errors occurred. A higher parameter
code indicates that the error event occurred later in time.
Each parameter entry is 10 bytes long and has the following format:
Table 6-19: Error Event format
Byte Offset Meaning
0 – 4
5
6 – 9
Result Message (see Diagnostic Clause)
Unused
Time-stamp (number of 1 minute increments since power-on)
When the log page becomes full, no more entries will be added until the log is cleared (using one of the methods
described previously) or a reset occurs. The current cumulative values will be returned regardless of the page
control field in the LOG SENSE CDB.