39
GB
Maintenance
Maintenance
4 Insert the new lamp all the way in until
it is securely in place. Tighten the
screws. Fold up the handle.
• Be careful not to touch the glass surface
of the lamp.
• The power will not turn on if the lamp is
not secured properly.
5 Close the lamp cover and tighten the
screws.
• Do not tighten the screws too much.
Doing so could damage some of the
internal components of the projector.
6 Turn the projector back over.
7 Connect the power cord and turn the
projector to standby mode.
8 Press the following keys on the
control panel in the following order
for less than five seconds each:
RESET, <, ,, ENTER.
• Do not put your hands into the lamp
replacement spot, or not fall any liquid or
object into it to avoid electrical shock or
fire.
• Be sure to use the LMP-P260 Projector
Lamp for replacement. If you use lamps
other than LMP-P260, the projector may
cause a malfunction.
• Be sure to turn off the projector and unplug
the power cord before replacing the lamp.
• We recommend that you also clean the air
filter whenever you replace the lamp.
The air filter should be cleaned every 1500
hours.
Remove dust from the outside of the
ventilation holes with a vacuum cleaner.
When it becomes difficult to remove the dust
from the filter with a vacuum cleaner,
remove the air filter and wash it.
1 Turn off the power and unplug the
power cord.
2 Remove the air filter cover.
Notes
Note
Caution
Notes
Cleaning the Air Filter